Measuring ranges from 100°C to 2500 °C
Universal pyrometer- KTRD 1550
Description
Performance, precision and reliability – you can count on MAURER pyrometers. Benefit from maximum adaptability by
choosing the right optics, accessories and the appropriate interface. Thus our pyrometer fits perfectly into existing
systems.
The most important features and characteristics at a glance:
- Spectral range: 5,0 μm
- Short response time from 0,5 to 5ms
- Emissivity from 100 – 10 %, adjustable directly at the pyrometer or via interface
- Available with either light beam aiming device (LED / Laser) or viewfinder
- With Vario-optic for exact focusing on the measuring spot
- Use with digital and analogue output
- 1 limit output (open collector)
- Grid connection 24 V DC
- Free Software (IR-LOG) for parameter setting, data recording and storage
Measuring Ranges
1. 100 – 1800 °C
2. 300 – 2500 °C
* Special measuring ranges upon request
Scope of Applications:
Processing of ceramics and glass
Technical Data
| Device type | KTRD 1550-1 oder KTRD 1550-2 | |
| Target marking | light beam aiming device green LED or laser (KTRD 1550-1), viewfinder (KTRD 1550-2) | |
| Response time | Measuring range 1: 5ms; measuring range 2: 0,5 ms | |
| Spectral range | 5,0 μm | |
| Measuring uncertainity | 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T95 = 1 s) | |
| Reproducibility | 0,1% of meas.value in °C ± 1°C (ε = 1, Tamb. = 23°C, T 95 = 1s) | |
| Emissivityε | 100 – 10 % adjustable at the unit or through interface | |
| Resolution | < 0,1 % at the analogue output < 0,1 °C at the interface | |
| Operating / Storage temperature | 0 – 50 °C, Optics 150 °C / -10 – 70 °C 32 – 140 °F, Optics 302 °F / 14 – 158 °F | |
| Permissible humidity | 35 – 85 % RH (non-condensing) | |
| Analogue output | 0 – 20 mA / 4 – 20 mA (Load max. 500 Ω) | |
| Subranges | freely adjustable within measuring range | |
| limit output (open collector) | 24 V 100 mA | |
| Interface | RS 232 ± 50 V isolated or RS 485 ± 70 V isolated Optional: PROFIBUS, PROFINET, Ethernet, EtherCAT, USB 2.0 |
|
| Maximum value memory | Maximum memory, peak value memory double, adjustable time and threshold value, erasing after time, external contact, by software, after every measuring object |
|
| Supply voltage | 24 V DC ± 10 % | |
| Power consumption | < 100 mA | |
| Device connection | 12-pol. plug connector | |
| Dimensions (LxHxW) / Weight | 54 x 54 x 147mm / 0,6 kg | |
| IP Code | IP65 | |
Configurations
- Built-in digital display on the backside of the pyrometer
- Extensive selection of objectives, suitable for your application
Optics:
Optics: IR 2050 T
Lense: F 50, Ø 25,4 mm
Measuring aperture: Ø 0,5 mm
| B[mm] | C[mm] | A[mm] | M[mm] |
|---|---|---|---|
| 240 | 206,0 | 13,0 | 2,5 |
| 300 | 270,1 | 8,9 | 3,1 |
| 400 | 373,7 | 5,3 | 3,9 |
| 500 | 474,9 | 4,1 | 5,0 |
| 800 | 777,2 | 1,8 | 8,7 |
| 1000 | 977,5 | 1,5 | 9,8 |
Datasheet
Assembly
| Mechanical Equipment | Electronic Equipment | Electronic process units |
|---|---|---|
| Blowing device | Connection cables | AED 1012 |
| Mounting parts | (Line-) Scanners | AED 1012-C PID Unit |
| Cooling case | Power Supply 100-270 VAC – 24 VDC | AED 1012-PC Program-Unit |
| Mirror 90° for beam deflection | PC-Box (USB-connection set) | |
| Optiken |