- KTRD 1105
- KTRD 1105-HS
Performance, precision and reliability – you can count on MAURER pyrometers. Benefit from maximum adaptability by choosing the right optics, accessories and the appropriate interface. Thus our pyrometer fits perfectly into existing systems.
The most important features and characteristics at a glance:
Measuring Ranges
1. (-40) – 800 °C / (-40) – 1472 °F
2. (-10) – 900 °C / 14 – 1652 °F
3. 0 – 100 °C / 32 – 212 °F
4. 0 – 500 °C / 32 – 932 °F
Special measuring ranges upon request / Subranges freely adjustable within measuring range
Scope of Applications
Processing of ceramics, rubber, paper, wood, food, asphalt, building material, electronic components, plastics, as well as plastic deep-drawing, lacquering drying, drying processes etc.
| Spectral range | 8 – 14 μm | |
| Target marking | Light beam aiming device (LED/Laser) | |
| Response time | < 100 ms | |
| Measurement uncertainty | 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s) | |
| Temperature dependence | 0,05 % / °C | |
| Reproducibility | 0,1 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s) | |
| Emissivity | 100 – 10 %, adjustable directly at the pyrometer or via interface | |
| Resolution | < 0,1 % at the analogue output < 0,1 °C at the interface | |
| Operating / Storage temperature | 0 – 50 °C, Optics 150 °C / -10 – 70 °C 32 – 140 °F, Optics 302 °F / 14 – 158 °F | |
| Permissible humidity | 35 – 85 % RH (non-condensing) | |
| Analogue output | 0 – 20 mA / 4 – 20 mA (Load max. 500 Ω) | |
| 1 limit output (open collector) | 20 V 100 mA | |
| Interface | RS 232 ± 50 V isolated or RS 485 ± 70 V isolated Optional: PROFIBUS, PROFINET, Ethernet, EtherCAT, USB 2.0 |
|
| Maximum value memory | Maximum memory, peak value memory double, adjustable time and threshold value, erasing after time, external contact, by software, after every measuring object | |
| Supply voltage | 24 V DC ± 10 % | |
| Power consumption | < 100 mA | |
| Device connection | 12-pol. plug connector | |
| Dimensions (LxHxW) / Weight | 54 x 54 x 147mm / 0,6 kg | |
| IP Code | IP65 | |
Configurations:
| Devices | Measuring Ranges | Spectral range | Scope of Applications |
|---|---|---|---|
| KTRD 1105 | -20-1000°C (-4-1832°F) | 8-14μm | ceramics, rubber, paper, wood, food, asphalt, plastics, lacquering drying, drying process |
| KTRD 1550 | 100-2500°C (212-4532°F) | 5,0 μm | ceramics, glass, flat glass, glass surface, glass drop, hollow glass |
| KTRD 1065 | 100-1400°C (212-2552°F) | 2,1μm | steel, iron, non-ferrous metal, induction heating, soldering, tempering etc. |
| KTRD 1075 | 250-2500°C (572-4532°F) | 1,45-1,7μm | steel, iron, non-ferrous metal, wires, ceramic, rolling, induction heating, brazing, etc. |
| KTRD 1085 | 550-4000°C (1022-7232°F) | 0,85-1,1μm | steel, ceramic, glass feeder, hardening, rolling, induction heating, forging, etc. |
| KTRD 2300 | 50-1000°C (122-1832°F) | 2,3μm | steel, iron, non-ferrous metal, induction heating, soldering, tempering etc. |
| Mechanical Equipment | Electronic Equipment | Electronic process units |
|---|---|---|
| Objectives | Connection cables | AED 1012 |
| Mounting parts | (Line-) Scanners | AED 1012-C PID Regler |
| Cooling case | Power Supply 100-270 VAC – 24 VDC | AED 1012-PC Programm-Regler |
| Mirror 90° for beam deflection | PC-Box (USB-connection set) | |
| Blowing device | ||