Universal pyrometer- KTRD 1550

Measuring ranges from 100°C to 2500 °C

Description

Performance, precision and reliability – you can count on MAURER pyrometers. Benefit from maximum adaptability by
choosing the right optics, accessories and the appropriate interface. Thus our pyrometer fits perfectly into existing
systems.

The most important features and characteristics at a glance:

  • Spectral range: 5,0 μm
  • Short response time from 0,5 to 5ms
  • Emissivity from 100 – 10 %, adjustable directly at the pyrometer or via interface
  • Available with either light beam aiming device (LED / Laser) or viewfinder
  • With Vario-optic for exact focusing on the measuring spot
  • Use with digital and analogue output
  • 1 limit output (open collector)
  • Grid connection 24 V DC
  • Free Software (IR-LOG) for parameter setting, data recording and storage

 

Measuring Ranges

1. 100 – 1800 °C
2. 300 – 2500 °C
* Special measuring ranges upon request

 

Scope of Applications: 

Processing of ceramics and glass

 

Technical Data

Device type KTRD 1550-1 oder KTRD 1550-2
Target marking light beam aiming device green LED or laser (KTRD 1550-1), viewfinder (KTRD 1550-2)
Response time Measuring range 1: 5ms; measuring range 2: 0,5 ms
Spectral range 5,0 μm
Measuring uncertainity 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T95 = 1 s)
Reproducibility 0,1% of meas.value in °C ± 1°C (ε = 1, Tamb. = 23°C, T 95 = 1s)
Emissivityε 100 – 10 % adjustable at the unit or through interface
Resolution < 0,1 % at the analogue output < 0,1 °C at the interface
Operating / Storage temperature 0 – 50 °C, Optics 150 °C / -10 – 70 °C 32 – 140 °F, Optics 302 °F / 14 – 158 °F
Permissible humidity 35 – 85 % RH (non-condensing)
Analogue output 0 – 20 mA / 4 – 20 mA (Load max. 500 Ω)
Subranges freely adjustable within measuring range
limit output (open collector) 24 V 100 mA
Interface RS 232 ± 50 V isolated or RS 485 ± 70 V isolated
Optional: PROFIBUS, PROFINET, Ethernet, EtherCAT, USB 2.0
Maximum value memory Maximum memory, peak value memory double, adjustable time and threshold value, erasing
after time, external contact, by software, after every measuring object
Supply voltage 24 V DC ± 10 %
Power consumption < 100 mA
Device connection 12-pol. plug connector
Dimensions (LxHxW) / Weight 54 x 54 x 147mm / 0,6 kg
IP Code IP65

 

Configurations

  • Built-in digital display on the backside of the pyrometer
  • Extensive selection of objectives, suitable for your application

 

Optics:

Optics: IR 2050 T
Lense: F 50, Ø 25,4 mm
Measuring aperture: Ø 0,5 mm

B[mm] C[mm] A[mm] M[mm]
240 206,0 13,0 2,5
300 270,1 8,9 3,1
400 373,7 5,3 3,9
500 474,9 4,1 5,0
800 777,2 1,8 8,7
1000 977,5 1,5 9,8

Datasheet

 

Assembly

Mechanical Equipment Electronic Equipment Electronic process units
Blowing device Connection cables AED 1012
Mounting parts (Line-) Scanners AED 1012-C PID Unit
Cooling case Power Supply 100-270 VAC – 24 VDC AED 1012-PC Program-Unit
Mirror 90° for beam deflection PC-Box (USB-connection set)
Optiken